Evaluasi Perbandingan Informasi Citra MRI Brain Sekuen Diffusion Weighted Imaging Irisan Axial Pada Variasi Nilai SENSE di Instalasi Radiologi RSUD Provinsi NTB

Authors

  • I Made Lana Prasetya Akademi Teknik Radiodiagnostik dan Radioterapi Bali
  • I Bagus Gede Dharmawan Akademi Teknik Radiodiagnostik dan Radioterapi Bali
  • I Wayan Ariec Sugiantara Akademi Teknik Radiodiagnostik dan Radioterapi Bali
  • Nandika A.J Mokoagow Akademi Teknik Radiodiagnostik dan Radioterapi Bali

DOI:

https://doi.org/10.59841/an-najat.v1i4.551

Keywords:

MRI, DWI, SENSE, MRI Brain, Anatomical Information

Abstract

Magnetic Resonance is a radiodiagnostic examination tool in the field of radiology, especially in the medical world. Diffusion Weighted Imaging is a method to assess molecular function and microarchitecture of the human body. DWI signal contrast can be measured with visible diffusion coefficient maps and serves as a tool for treatment response evaluation and disease progression assessment. Parallel imaging techniques involve phased array coils to process signals from a slice, then combine these slices to form an image, reducing scan time by reducing the acquired K-space lines. The formation of Sensitivity Encoding (SENSE) can shorten the insertion of K-space. This study aims to test variations of SENSE values 2.0 and 2.5 in MRI brain examinations with axial DWI sequences that are capable of visualizing anatomical information with fast scan times without compromising image quality, resulting in optimal images. This research is quantitative with an experimental approach. The sample consists of 10 patients using voluntary sampling of MRI Brain with axial DWI sequence and varying SENSE values from July to August 2023. Data were collected through questionnaires filled out by three radiology specialists at the Radiology Installation of the Provincial Hospital of West Nusa Tenggara (RSUD Provinsi NTB). The results of the Wilcoxon test showed a significant difference in anatomical information in MRI brain with axial DWI sequences between SENSE values of 2 and 2.5, with a p-value of 0.012. The mean rank value results indicated a sum of ranks of 280.00 for the SENSE 2 value, demonstrating greater optimality compared to SENSE 2.5. This study concludes that there is a significant difference in anatomical information in MRI brain with axial DWI sequences between SENSE values of 2 and 2.5. SENSE 2 tends to provide more optimal information.

References

Vranic JE, Cross NM, Wang Y, Hippe DS, De Weerdt E, Mossa-Basha MMD. Compressed sensing-sensitivity encoding (CS-SENSe) accelerated brain imaging: Reduced scan time without reduced image quality. Am J Neuroradiol. 2019;40(1):92–8.

Notosiswoyo M, Suswati S. Pemanfaatan Magnetic Resonance (MRI) Sebagai Sarana Diagnosa Pasien. 2018;XIV(3):8–13.

Drake-Pérez M, Boto J, Fitsiori A, Lovblad K, Vargas MI. Clinical applications of diffusion weighted imaging in neuroradiology. Insights Imaging. 2018.

Baliyan V, Das CJ, Sharma R, Gupta AK. Diffusion weighted imaging: Technique and applications. World J Radiol. 2016.

Westbrook C. HandBook of MRI Technique. fifth edit. 2014. Available from: https://www.ptonline.com/articles/how-to-get-better-mfi-results.

Liney G. “MRI From A to Z.” A Definitive Guide for Medical Professionals. Vols. s13-I, Notes and Queries. 2013.

Westbrook, Catherine dan JT. MRI in Practice Fifth Edition.United Kingdom: Wiley-Blackwel: UK. 2019.

Sartoretti E, Sartoretti T, Binkert C, Najafi A, Schwenk Á, Hinnen M, et al. Reduction of procedure times in routine clinical practice with Compressed SENSE magnetic resonance imaging technique. PLoS One. 2019.

Robert W. Brown PD. Magnetic Resonance Imaging: Physical Principles and Sequence Design. Second Edition. 2015.

Deshmane A, Gulani V, Griswold MA, Seiberlich N. Parallel MR imaging. J Magn Reson Imaging. 2012.

Downloads

Published

2023-10-24

How to Cite

I Made Lana Prasetya, I Bagus Gede Dharmawan, I Wayan Ariec Sugiantara, & Nandika A.J Mokoagow. (2023). Evaluasi Perbandingan Informasi Citra MRI Brain Sekuen Diffusion Weighted Imaging Irisan Axial Pada Variasi Nilai SENSE di Instalasi Radiologi RSUD Provinsi NTB. An-Najat, 1(4), 245–253. https://doi.org/10.59841/an-najat.v1i4.551

Similar Articles

1 2 > >> 

You may also start an advanced similarity search for this article.