Gambaran Kadar Perak (Ag) Pada Limbah Cair Fixer Di Instalasi Radiologi Rumah Sakit Pertamedika Ummi Rosnati Banda Aceh

Authors

  • Pocut Zairiana Finzia STIKes SIhat Beurata Banda Aceh
  • Dewi Febriyanti STIKes Sihat Beurata Banda Aceh
  • Adam S STIKes Sihat Beurata Banda Aceh

DOI:

https://doi.org/10.59841/jumkes.v2i4.2330

Keywords:

Silver Content, Description

Abstract

A study on the description of silver (Ag) levels in liquid waste fixer originating from a radiology installation before being processed at the Waste Treatment Installation is sometimes necessary to avoid environmental pollution. The time and place of this research were conducted at the radiology installation for approximately 1 (one) month. The purpose of this writing is to determine the description of the silver (Ag) levels of fixer in the radiology installation. This research method is field observation. and the processing of silver levels was carried out at the Medan standardization research agency (baristand) with researchers sending samples of 100 mg/l to be tested for silver levels. The thing studied in this study was to determine the description of silver levels using the Atomic Absorption Spectrophotometry (AAS) method. From the observation results after processing, the Ag content was 0.03 mg/L. After processing, the silver content was allowed to be discharged directly into the environment or public channels because the results were still below the established quality standards, namely 5.0 mg/L. However, it would be better if each hospital was advised to process the liquid waste at the Wastewater Treatment Plant to avoid environmental pollution.

References

Departemen Kesehatan RI. 2002. Pedoman Sanitasi Rumah Sakit di Indonesia.

Jakarta : direktorat Jenderal PPM & PPL dan Direktorat Jenderal

Pelayanan Medik.

Djoko, Barlin. 1995. Pengaruh Limbah Rumah Sakit Terhadap Kesehatan,

Edisi 1. Fakultas Kesehatan Masyarakat Universitas Indonesia.

James. 1991. Kajian Pengelolaan Limbah Cair Rumah Sakit Edisi 1. Jawa

Barat.

Notoadmojo. 2010. Metode Penelitian. Edisi 2010. Poltekes Semarang.

Rasad, Sjahriar. 2005. Radiologi Diagnostik Edisi 2, FKUI. Jakarta Pusat.

Sanusi, Said. 2002. Uji performance Pengolahan Air Limbah Rumah Sakit

Dengan Proses Biofilter Tercelup. Edisi 2002. Jakarta Pusat.

Soemirat, Slamet. 1994. Jenis Limbah Rumah Sakit Dan Dampaknya Terhadap

Kesehatan Serta Lingkungan. Edisi khusus. Rumah Sakit Semarang.

Tyoso, 1995. Pengolahan dan penanganan limbah cair, Edisi 2 Departemen

Kesehatan Republik Indonesia.

Win Priantoro, 2011. Radiofotografi 1, Edisi 2011. Poltekes Kemenkes Jakarta.

Wardhana, 1995. Manajemen Limbah Rumah Sakit, Edisi 1. Yogyakarta.

Downloads

Published

2024-10-30

How to Cite

Pocut Zairiana Finzia, Dewi Febriyanti, & Adam S. (2024). Gambaran Kadar Perak (Ag) Pada Limbah Cair Fixer Di Instalasi Radiologi Rumah Sakit Pertamedika Ummi Rosnati Banda Aceh. Jurnal Mahasiswa Ilmu Kesehatan, 2(4), 263–272. https://doi.org/10.59841/jumkes.v2i4.2330

Similar Articles

You may also start an advanced similarity search for this article.